Neurol. praxi. 2017;18(4):233-237 | DOI: 10.36290/neu.2017.091

Detection and evaluation of vertebral arterial stenoses

MUDr. Ondřej Škoda, Ph.D.
Neurologické oddělení, Nemocnice Jihlava, p.o.
Neurologická klinika 3. LF UK a FN Královské Vinohrady, Praha

Color duplex sonography, performed according to exact protocol, is a suitable and accurate imaging method of first choice forthe detection and evaluation of vertebral arterial stenoses. In this overview article we offer detailed methodology of examination,detection of direct and indirect signs of the stenosis and classification of hemodynamic parameters, including reference valuesfrom our own research. We also briefly comment clinical importance of findings in vertebral arteries and their position in thediagnostic and therapeutic algorhitm for patients with vertebrobasilar ischemia.

Keywords: vertebral stenosis, color duplex sonography, detection, evaluation, vertebrobasilar ischemia

Published: October 1, 2017  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Škoda O. Detection and evaluation of vertebral arterial stenoses. Neurol. praxi. 2017;18(4):233-237. doi: 10.36290/neu.2017.091.
Download citation

References

  1. Albuquerque FC, Fiorella D, Han P, Spetzler RF, McDougall CG. A reappraisal of angioplasty and stenting for the treatment of vertebral origin stenosis. Neurosurgery 2003; 53: 607-616. Go to original source... Go to PubMed...
  2. Bar M, Škoda O, Školoudík D. Duplexní sonografie extrakraniálních tepen - národní standard vyšetření v rámci funkční specializace v neurosonologii - odborná příloha. Ces Slov Neurol Neurochir 2002; Suppl. 2: 8-12.
  3. Caplan LR, Tettenborn B. Vertebrobasilar occlusive disease: review of selected aspects. Spontaneous dissection of extracranial and intracranial posterior circulation arteries. Cerebrovasc Dis 1992; 2: 256-265. Go to original source...
  4. Cartlidge NE, Whisnant JP, Evelback LR. Carotid and vertebral-basilar Transient cerebral ischemic attacks. A Community Study, Rochester, Minnesota. Mayo Clin Proc 1977; 52: 117-120.
  5. DeBray JM, Pasco A, Tranquart F, Papon X, Alecu C, Giraudeau B, Dubas F, Emile J. Accuracy of color-doppler in the quantification of proximal vertebral artery stenoses. Cerebrovasc. Dis. 2001; 11: 335-340. Go to original source... Go to PubMed...
  6. Flosmann E, Rothwell PM. Prognosis of vertebrobasilar transient ischaemic attack and minor stroke. Brain 2003; 9: 1940-1954. Go to original source...
  7. Haynes MJ, Hart R, McGeachie J. Vertebral arteries and neck rotation: Doppler velocimeter interexaminer reliability. Ultrasound Med Biol 2000; 8: 1363-1367. Go to original source...
  8. Hua Y, Meng X-F, Jia L-Y, Ling Ch, Miao Z-R, Ling F, Liu J-B. Color doppler imaging evaluation of proximal vertebral artery stenosis. AJR Am J Roentgenol 2009; 193: 1434-1438. Go to original source... Go to PubMed...
  9. Chastain HD, Campbell MS, Iyer S, Roubin GS, Vitek J, Mathur A, Al-Mubarak NA, Terry JB, Yates V, Kretzer K, Alfred D, Gomez CR. Extracranial vertebral artery stent placement: In-hospital and Follow-up results. J Neurosurg 1999; 91: 547-552. Go to original source... Go to PubMed...
  10. Khan S, Rich P, Clifton A, Markus HS. Noninvasive detection of vertebral artery stenosis: a comparison of contrast - enhanced MR angiography, CT Angiography, and ultrasound. stroke 2009; 40: 3499-3503. Go to original source... Go to PubMed...
  11. Koch S, Romano JG, Park H, Amir M, Forteza AM. Ultrasound velocity criteria for vertebral origin stenosis. J Neuroimaging 2008; 20: 1-5.
  12. Markus HS, van der Worp HB, Rothwell PM. Posterior circulation ischaemic stroke and transient ischaemic attack: diagnosis, investigation, and secondary prevention. Lancet Neurol 2013; 12(10): 989-9810. Go to original source...
  13. Marquardt L, Kuker W, Chandratheva A, Geraghty O, Rothwell PM. Incidence and prognosis of 50 % symptomatic vertebral or basilar artery stenosis: prospective population-based study. Brain 2009; 132(4): 982-988. Go to original source... Go to PubMed...
  14. Mumenthaler M, Mattle H. Neurologie. Praha: Grada (lic. Thieme Verlag) 2001: 652.
  15. Puchner S, Haumer M, Rand T, Reiter M, Minar E, Lammer J, Bucek RA. CTA in the detection and quantification of vertebral artery pathologies: a correlation with color doppler sonography. Neuroradiology 2007; 49: 645-650. Go to original source... Go to PubMed...
  16. Škoda O, Bar M, Školoudík D. Duplexní sonografie extrakraniálních tepen - národní standard vyšetření v rámci funkční specializace v neurosonologii. Ces Slov Neurol Neurochir 2002; Suppl. 2: 5-8.
  17. Škoda O, Kalvach P, Procházka B, Svárovský M. Non-invasive evaluation of proximal vertebral artery stenosis using color Doppler sonography and CT angiography. J Neuroradiol 2014; 41(5): 336-341. Go to original source... Go to PubMed...
  18. Školoudík D, Škoda O, Bar M, Brozman M, Václavík D. Neurosonologie: Duplexní sonografie subklaviálně - vertebrální oblasti. Praha: Galén 2003: 92-115.
  19. Wehman JC, Hanel RA, Guidot CA, Guterman LR, Hopkins LN. Atherosclerotic occlusive extracranial vertebral artery disease: indications for intervention, endovascular techniques, short-term and long-term results. J Interven Car21. Yurdakul M, Tola M. Doppler criteria for identifying proximal vertebral artery stenosis of 50 % or more. J Ultrasound Med 2011; 30: 163-168. Go to original source... Go to PubMed...
  20. Whisnant JP, Cartlidge NE, Evelbach LR. Carotid and Vertebral-basilar transient Ischemic attacks: effects of anticoagulants, hypertension and cardiac disorders on survival and stroke occurence - a population study. Ann Neurol 1978; 3: 107-115. Go to original source... Go to PubMed...




Neurology for Practice

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.